Converting a variable frequency to TTL HIGH and LOW levels, based on a fixed (possible non-fixed?) frequencySwitching relay with a PNP and TTL levelsMC34063A: Why am I overclocking this chip?Changing Low Frequency to High FrequencyDebouncing a TTL Photodiode DetectorHow to make a AC current source of variable low frequency and variable low amplitudeOp-amp for pulse width modulation, 5v single rail supplyConverting varying frequency and duty cycle to varying frequency fixed duty cycleState Variable Filter - Unexpected High Frequency BehaviorMulti PWM switch with mosfetAmplification of sinusoidal signal from filter circuit

Brexit - No Deal Rejection

Why do tuner card drivers fail to build after kernel update to 4.4.0-143-generic?

Are relativity and doppler effect related?

What are substitutions for coconut in curry?

Describing a chess game in a novel

Passing arguments from one script to another

Shortcut for setting origin to vertex

Does this sum go infinity?

Is it true that good novels will automatically sell themselves on Amazon (and so on) and there is no need for one to waste time promoting?

Is a party consisting of only a bard, a cleric, and a warlock functional long-term?

I got the following comment from a reputed math journal. What does it mean?

As a new Ubuntu desktop 18.04 LTS user, do I need to use ufw for a firewall or is iptables sufficient?

My adviser wants to be the first author

What exactly is this small puffer fish doing and how did it manage to accomplish such a feat?

Did Ender ever learn that he killed Stilson and/or Bonzo?

How to terminate ping <dest> &

How to write cleanly even if my character uses expletive language?

Min function accepting varying number of arguments in C++17

How to make healing in an exploration game interesting

What is the adequate fee for a reveal operation?

How could an airship be repaired midflight?

Print a physical multiplication table

Why Choose Less Effective Armour Types?

Adventure Game (text based) in C++



Converting a variable frequency to TTL HIGH and LOW levels, based on a fixed (possible non-fixed?) frequency


Switching relay with a PNP and TTL levelsMC34063A: Why am I overclocking this chip?Changing Low Frequency to High FrequencyDebouncing a TTL Photodiode DetectorHow to make a AC current source of variable low frequency and variable low amplitudeOp-amp for pulse width modulation, 5v single rail supplyConverting varying frequency and duty cycle to varying frequency fixed duty cycleState Variable Filter - Unexpected High Frequency BehaviorMulti PWM switch with mosfetAmplification of sinusoidal signal from filter circuit













1












$begingroup$


I have a square output from an LM324 op-amp (0 and 5 volts) which has a frequency between 1 to 500 Hz (yes, low frequencies). I would like to find a simple way to have HIGH TTL signal when it is over 50 Hz and a LOW when it is below that. It's not necessary to be so precise, but around 50 Hz will be fine. I know that I can do it by uCs, and I did it. However I have 1500 outputs which I should make a network from, and I would like to make it cheap and fast.



More info about the signal: The frequency is almost fixed at something above 50, say 150Hz or may be 250Hz or so, and the frequency variation is less than 10 Hz, then suddenly it will drop to less than 50, stays for a minute and again back up.



Finally: Is there a way I can control this 50Hz threshold by uC?










share|improve this question











$endgroup$











  • $begingroup$
    High pass filter?
    $endgroup$
    – Linkyyy
    2 hours ago










  • $begingroup$
    nope! it is still a frequency over 50 Hz, I need a near-flat voltage at different levels below and over the treshold.
    $endgroup$
    – sina rahbari
    2 hours ago










  • $begingroup$
    on in another word, simply: how to know if a frequency is higher or lower than a value? represent in 0 or 1, 0 or 5 volts?
    $endgroup$
    – sina rahbari
    2 hours ago










  • $begingroup$
    A high pass filter sounds like a good start, since it turns any frequency lower than your value to (close to) zero.
    $endgroup$
    – Hearth
    2 hours ago















1












$begingroup$


I have a square output from an LM324 op-amp (0 and 5 volts) which has a frequency between 1 to 500 Hz (yes, low frequencies). I would like to find a simple way to have HIGH TTL signal when it is over 50 Hz and a LOW when it is below that. It's not necessary to be so precise, but around 50 Hz will be fine. I know that I can do it by uCs, and I did it. However I have 1500 outputs which I should make a network from, and I would like to make it cheap and fast.



More info about the signal: The frequency is almost fixed at something above 50, say 150Hz or may be 250Hz or so, and the frequency variation is less than 10 Hz, then suddenly it will drop to less than 50, stays for a minute and again back up.



Finally: Is there a way I can control this 50Hz threshold by uC?










share|improve this question











$endgroup$











  • $begingroup$
    High pass filter?
    $endgroup$
    – Linkyyy
    2 hours ago










  • $begingroup$
    nope! it is still a frequency over 50 Hz, I need a near-flat voltage at different levels below and over the treshold.
    $endgroup$
    – sina rahbari
    2 hours ago










  • $begingroup$
    on in another word, simply: how to know if a frequency is higher or lower than a value? represent in 0 or 1, 0 or 5 volts?
    $endgroup$
    – sina rahbari
    2 hours ago










  • $begingroup$
    A high pass filter sounds like a good start, since it turns any frequency lower than your value to (close to) zero.
    $endgroup$
    – Hearth
    2 hours ago













1












1








1





$begingroup$


I have a square output from an LM324 op-amp (0 and 5 volts) which has a frequency between 1 to 500 Hz (yes, low frequencies). I would like to find a simple way to have HIGH TTL signal when it is over 50 Hz and a LOW when it is below that. It's not necessary to be so precise, but around 50 Hz will be fine. I know that I can do it by uCs, and I did it. However I have 1500 outputs which I should make a network from, and I would like to make it cheap and fast.



More info about the signal: The frequency is almost fixed at something above 50, say 150Hz or may be 250Hz or so, and the frequency variation is less than 10 Hz, then suddenly it will drop to less than 50, stays for a minute and again back up.



Finally: Is there a way I can control this 50Hz threshold by uC?










share|improve this question











$endgroup$




I have a square output from an LM324 op-amp (0 and 5 volts) which has a frequency between 1 to 500 Hz (yes, low frequencies). I would like to find a simple way to have HIGH TTL signal when it is over 50 Hz and a LOW when it is below that. It's not necessary to be so precise, but around 50 Hz will be fine. I know that I can do it by uCs, and I did it. However I have 1500 outputs which I should make a network from, and I would like to make it cheap and fast.



More info about the signal: The frequency is almost fixed at something above 50, say 150Hz or may be 250Hz or so, and the frequency variation is less than 10 Hz, then suddenly it will drop to less than 50, stays for a minute and again back up.



Finally: Is there a way I can control this 50Hz threshold by uC?







arduino operational-amplifier frequency ttl conversion






share|improve this question















share|improve this question













share|improve this question




share|improve this question








edited 56 mins ago









SamGibson

11.4k41738




11.4k41738










asked 2 hours ago









sina rahbarisina rahbari

83




83











  • $begingroup$
    High pass filter?
    $endgroup$
    – Linkyyy
    2 hours ago










  • $begingroup$
    nope! it is still a frequency over 50 Hz, I need a near-flat voltage at different levels below and over the treshold.
    $endgroup$
    – sina rahbari
    2 hours ago










  • $begingroup$
    on in another word, simply: how to know if a frequency is higher or lower than a value? represent in 0 or 1, 0 or 5 volts?
    $endgroup$
    – sina rahbari
    2 hours ago










  • $begingroup$
    A high pass filter sounds like a good start, since it turns any frequency lower than your value to (close to) zero.
    $endgroup$
    – Hearth
    2 hours ago
















  • $begingroup$
    High pass filter?
    $endgroup$
    – Linkyyy
    2 hours ago










  • $begingroup$
    nope! it is still a frequency over 50 Hz, I need a near-flat voltage at different levels below and over the treshold.
    $endgroup$
    – sina rahbari
    2 hours ago










  • $begingroup$
    on in another word, simply: how to know if a frequency is higher or lower than a value? represent in 0 or 1, 0 or 5 volts?
    $endgroup$
    – sina rahbari
    2 hours ago










  • $begingroup$
    A high pass filter sounds like a good start, since it turns any frequency lower than your value to (close to) zero.
    $endgroup$
    – Hearth
    2 hours ago















$begingroup$
High pass filter?
$endgroup$
– Linkyyy
2 hours ago




$begingroup$
High pass filter?
$endgroup$
– Linkyyy
2 hours ago












$begingroup$
nope! it is still a frequency over 50 Hz, I need a near-flat voltage at different levels below and over the treshold.
$endgroup$
– sina rahbari
2 hours ago




$begingroup$
nope! it is still a frequency over 50 Hz, I need a near-flat voltage at different levels below and over the treshold.
$endgroup$
– sina rahbari
2 hours ago












$begingroup$
on in another word, simply: how to know if a frequency is higher or lower than a value? represent in 0 or 1, 0 or 5 volts?
$endgroup$
– sina rahbari
2 hours ago




$begingroup$
on in another word, simply: how to know if a frequency is higher or lower than a value? represent in 0 or 1, 0 or 5 volts?
$endgroup$
– sina rahbari
2 hours ago












$begingroup$
A high pass filter sounds like a good start, since it turns any frequency lower than your value to (close to) zero.
$endgroup$
– Hearth
2 hours ago




$begingroup$
A high pass filter sounds like a good start, since it turns any frequency lower than your value to (close to) zero.
$endgroup$
– Hearth
2 hours ago










2 Answers
2






active

oldest

votes


















1












$begingroup$

One way to solve this problem is to use a re-triggerable one-shot component. You said that absolute tolerance is not super critical and so the typical tolerances of a one-shot may be a suitable and simple means to detect the frequency shift of your signal.



The one-shot needs to be setup with a R/C timing delay just at the timing period of your signal at 50Hz. This would be 20msec. As long as the input trigger signal at the one-shot stays above the 50Hz rate the output of the one-shot will stay re-triggered at a high level. When the input frequency drops below 50Hz the one-shot will start to timeout on each input pulse and its output will start to pulse with each cycle of the lower frequency input.



You could possibly use this as is depending upon what you are using to detect the frequency changes or you could add some additional simple logic to convert the lower frequency pulsing output of the one-shot to a static signal envelope. I'll leave that detail for you to figure out in the case you find this re-triggerable one-shot idea suitable to your application.






share|improve this answer









$endgroup$




















    1












    $begingroup$

    You have multiple alternatives, each one of them with different trade offs.



    • The conceptually simplest and most precise one, would be to use a pulse counter.

    This is probably what you implemented with your micro controller. Gate a known fast clock with each cycle of the input signal and compare that count to a reference.



    • Translate that same idea to the analog domain. Using a ramp as the “counter”.

    Start a known slew-rate ramp with an edge of the signal and capture the value on the next edge. Compare this value to a reference. Monolithic latching comparators make this simpler than it sounds.



    • Use a retriggerable monostable. With the duration being the comparison value.

    A retriggerable monostable with a period of 20ms will remain triggered as long as the signal is above 50Hz, and will generate pulses when it’s below that. A second retriggerable monostable can “filter” these pulses into a continuous signal.



    • use a filter slope and a peak detector (just as some cheap FM radios)

    A filter slope (high-pass or low-pass will do) attenuates different frequencies differently. By detecting the amplitude of the output signal you can compare to a threshold. The higher the filter slope the higher the frequency gain.



    • use a known pulse size to convert to PWM. (Frequency to voltage conversion).

    By triggering a known-size pulse with each signal edge (with a monostable or just an edge detector) you convert the signal to PWM whose DC average will be proportional to the frequency. You can then use an analog comparator to detect the transition.



    Given that you are talking of thousands of signals, any analog solution might be difficult to use reliably with a desired tolerance. Besides, you will need multiple components for each channel; at least 1 IC and multiple passives.



    If you simply program a 14-pin microcontroller to implement just this function on several channels, you can use 1 IC for 5 channels or so. With much better precision, reliability, and repeatability. Even a 6-pin micro at 1 IC per channel would be smaller and simpler.






    share|improve this answer









    $endgroup$












      Your Answer





      StackExchange.ifUsing("editor", function ()
      return StackExchange.using("mathjaxEditing", function ()
      StackExchange.MarkdownEditor.creationCallbacks.add(function (editor, postfix)
      StackExchange.mathjaxEditing.prepareWmdForMathJax(editor, postfix, [["\$", "\$"]]);
      );
      );
      , "mathjax-editing");

      StackExchange.ifUsing("editor", function ()
      return StackExchange.using("schematics", function ()
      StackExchange.schematics.init();
      );
      , "cicuitlab");

      StackExchange.ready(function()
      var channelOptions =
      tags: "".split(" "),
      id: "135"
      ;
      initTagRenderer("".split(" "), "".split(" "), channelOptions);

      StackExchange.using("externalEditor", function()
      // Have to fire editor after snippets, if snippets enabled
      if (StackExchange.settings.snippets.snippetsEnabled)
      StackExchange.using("snippets", function()
      createEditor();
      );

      else
      createEditor();

      );

      function createEditor()
      StackExchange.prepareEditor(
      heartbeatType: 'answer',
      autoActivateHeartbeat: false,
      convertImagesToLinks: false,
      noModals: true,
      showLowRepImageUploadWarning: true,
      reputationToPostImages: null,
      bindNavPrevention: true,
      postfix: "",
      imageUploader:
      brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
      contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
      allowUrls: true
      ,
      onDemand: true,
      discardSelector: ".discard-answer"
      ,immediatelyShowMarkdownHelp:true
      );



      );













      draft saved

      draft discarded


















      StackExchange.ready(
      function ()
      StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f427566%2fconverting-a-variable-frequency-to-ttl-high-and-low-levels-based-on-a-fixed-po%23new-answer', 'question_page');

      );

      Post as a guest















      Required, but never shown

























      2 Answers
      2






      active

      oldest

      votes








      2 Answers
      2






      active

      oldest

      votes









      active

      oldest

      votes






      active

      oldest

      votes









      1












      $begingroup$

      One way to solve this problem is to use a re-triggerable one-shot component. You said that absolute tolerance is not super critical and so the typical tolerances of a one-shot may be a suitable and simple means to detect the frequency shift of your signal.



      The one-shot needs to be setup with a R/C timing delay just at the timing period of your signal at 50Hz. This would be 20msec. As long as the input trigger signal at the one-shot stays above the 50Hz rate the output of the one-shot will stay re-triggered at a high level. When the input frequency drops below 50Hz the one-shot will start to timeout on each input pulse and its output will start to pulse with each cycle of the lower frequency input.



      You could possibly use this as is depending upon what you are using to detect the frequency changes or you could add some additional simple logic to convert the lower frequency pulsing output of the one-shot to a static signal envelope. I'll leave that detail for you to figure out in the case you find this re-triggerable one-shot idea suitable to your application.






      share|improve this answer









      $endgroup$

















        1












        $begingroup$

        One way to solve this problem is to use a re-triggerable one-shot component. You said that absolute tolerance is not super critical and so the typical tolerances of a one-shot may be a suitable and simple means to detect the frequency shift of your signal.



        The one-shot needs to be setup with a R/C timing delay just at the timing period of your signal at 50Hz. This would be 20msec. As long as the input trigger signal at the one-shot stays above the 50Hz rate the output of the one-shot will stay re-triggered at a high level. When the input frequency drops below 50Hz the one-shot will start to timeout on each input pulse and its output will start to pulse with each cycle of the lower frequency input.



        You could possibly use this as is depending upon what you are using to detect the frequency changes or you could add some additional simple logic to convert the lower frequency pulsing output of the one-shot to a static signal envelope. I'll leave that detail for you to figure out in the case you find this re-triggerable one-shot idea suitable to your application.






        share|improve this answer









        $endgroup$















          1












          1








          1





          $begingroup$

          One way to solve this problem is to use a re-triggerable one-shot component. You said that absolute tolerance is not super critical and so the typical tolerances of a one-shot may be a suitable and simple means to detect the frequency shift of your signal.



          The one-shot needs to be setup with a R/C timing delay just at the timing period of your signal at 50Hz. This would be 20msec. As long as the input trigger signal at the one-shot stays above the 50Hz rate the output of the one-shot will stay re-triggered at a high level. When the input frequency drops below 50Hz the one-shot will start to timeout on each input pulse and its output will start to pulse with each cycle of the lower frequency input.



          You could possibly use this as is depending upon what you are using to detect the frequency changes or you could add some additional simple logic to convert the lower frequency pulsing output of the one-shot to a static signal envelope. I'll leave that detail for you to figure out in the case you find this re-triggerable one-shot idea suitable to your application.






          share|improve this answer









          $endgroup$



          One way to solve this problem is to use a re-triggerable one-shot component. You said that absolute tolerance is not super critical and so the typical tolerances of a one-shot may be a suitable and simple means to detect the frequency shift of your signal.



          The one-shot needs to be setup with a R/C timing delay just at the timing period of your signal at 50Hz. This would be 20msec. As long as the input trigger signal at the one-shot stays above the 50Hz rate the output of the one-shot will stay re-triggered at a high level. When the input frequency drops below 50Hz the one-shot will start to timeout on each input pulse and its output will start to pulse with each cycle of the lower frequency input.



          You could possibly use this as is depending upon what you are using to detect the frequency changes or you could add some additional simple logic to convert the lower frequency pulsing output of the one-shot to a static signal envelope. I'll leave that detail for you to figure out in the case you find this re-triggerable one-shot idea suitable to your application.







          share|improve this answer












          share|improve this answer



          share|improve this answer










          answered 2 hours ago









          Michael KarasMichael Karas

          44.6k348103




          44.6k348103























              1












              $begingroup$

              You have multiple alternatives, each one of them with different trade offs.



              • The conceptually simplest and most precise one, would be to use a pulse counter.

              This is probably what you implemented with your micro controller. Gate a known fast clock with each cycle of the input signal and compare that count to a reference.



              • Translate that same idea to the analog domain. Using a ramp as the “counter”.

              Start a known slew-rate ramp with an edge of the signal and capture the value on the next edge. Compare this value to a reference. Monolithic latching comparators make this simpler than it sounds.



              • Use a retriggerable monostable. With the duration being the comparison value.

              A retriggerable monostable with a period of 20ms will remain triggered as long as the signal is above 50Hz, and will generate pulses when it’s below that. A second retriggerable monostable can “filter” these pulses into a continuous signal.



              • use a filter slope and a peak detector (just as some cheap FM radios)

              A filter slope (high-pass or low-pass will do) attenuates different frequencies differently. By detecting the amplitude of the output signal you can compare to a threshold. The higher the filter slope the higher the frequency gain.



              • use a known pulse size to convert to PWM. (Frequency to voltage conversion).

              By triggering a known-size pulse with each signal edge (with a monostable or just an edge detector) you convert the signal to PWM whose DC average will be proportional to the frequency. You can then use an analog comparator to detect the transition.



              Given that you are talking of thousands of signals, any analog solution might be difficult to use reliably with a desired tolerance. Besides, you will need multiple components for each channel; at least 1 IC and multiple passives.



              If you simply program a 14-pin microcontroller to implement just this function on several channels, you can use 1 IC for 5 channels or so. With much better precision, reliability, and repeatability. Even a 6-pin micro at 1 IC per channel would be smaller and simpler.






              share|improve this answer









              $endgroup$

















                1












                $begingroup$

                You have multiple alternatives, each one of them with different trade offs.



                • The conceptually simplest and most precise one, would be to use a pulse counter.

                This is probably what you implemented with your micro controller. Gate a known fast clock with each cycle of the input signal and compare that count to a reference.



                • Translate that same idea to the analog domain. Using a ramp as the “counter”.

                Start a known slew-rate ramp with an edge of the signal and capture the value on the next edge. Compare this value to a reference. Monolithic latching comparators make this simpler than it sounds.



                • Use a retriggerable monostable. With the duration being the comparison value.

                A retriggerable monostable with a period of 20ms will remain triggered as long as the signal is above 50Hz, and will generate pulses when it’s below that. A second retriggerable monostable can “filter” these pulses into a continuous signal.



                • use a filter slope and a peak detector (just as some cheap FM radios)

                A filter slope (high-pass or low-pass will do) attenuates different frequencies differently. By detecting the amplitude of the output signal you can compare to a threshold. The higher the filter slope the higher the frequency gain.



                • use a known pulse size to convert to PWM. (Frequency to voltage conversion).

                By triggering a known-size pulse with each signal edge (with a monostable or just an edge detector) you convert the signal to PWM whose DC average will be proportional to the frequency. You can then use an analog comparator to detect the transition.



                Given that you are talking of thousands of signals, any analog solution might be difficult to use reliably with a desired tolerance. Besides, you will need multiple components for each channel; at least 1 IC and multiple passives.



                If you simply program a 14-pin microcontroller to implement just this function on several channels, you can use 1 IC for 5 channels or so. With much better precision, reliability, and repeatability. Even a 6-pin micro at 1 IC per channel would be smaller and simpler.






                share|improve this answer









                $endgroup$















                  1












                  1








                  1





                  $begingroup$

                  You have multiple alternatives, each one of them with different trade offs.



                  • The conceptually simplest and most precise one, would be to use a pulse counter.

                  This is probably what you implemented with your micro controller. Gate a known fast clock with each cycle of the input signal and compare that count to a reference.



                  • Translate that same idea to the analog domain. Using a ramp as the “counter”.

                  Start a known slew-rate ramp with an edge of the signal and capture the value on the next edge. Compare this value to a reference. Monolithic latching comparators make this simpler than it sounds.



                  • Use a retriggerable monostable. With the duration being the comparison value.

                  A retriggerable monostable with a period of 20ms will remain triggered as long as the signal is above 50Hz, and will generate pulses when it’s below that. A second retriggerable monostable can “filter” these pulses into a continuous signal.



                  • use a filter slope and a peak detector (just as some cheap FM radios)

                  A filter slope (high-pass or low-pass will do) attenuates different frequencies differently. By detecting the amplitude of the output signal you can compare to a threshold. The higher the filter slope the higher the frequency gain.



                  • use a known pulse size to convert to PWM. (Frequency to voltage conversion).

                  By triggering a known-size pulse with each signal edge (with a monostable or just an edge detector) you convert the signal to PWM whose DC average will be proportional to the frequency. You can then use an analog comparator to detect the transition.



                  Given that you are talking of thousands of signals, any analog solution might be difficult to use reliably with a desired tolerance. Besides, you will need multiple components for each channel; at least 1 IC and multiple passives.



                  If you simply program a 14-pin microcontroller to implement just this function on several channels, you can use 1 IC for 5 channels or so. With much better precision, reliability, and repeatability. Even a 6-pin micro at 1 IC per channel would be smaller and simpler.






                  share|improve this answer









                  $endgroup$



                  You have multiple alternatives, each one of them with different trade offs.



                  • The conceptually simplest and most precise one, would be to use a pulse counter.

                  This is probably what you implemented with your micro controller. Gate a known fast clock with each cycle of the input signal and compare that count to a reference.



                  • Translate that same idea to the analog domain. Using a ramp as the “counter”.

                  Start a known slew-rate ramp with an edge of the signal and capture the value on the next edge. Compare this value to a reference. Monolithic latching comparators make this simpler than it sounds.



                  • Use a retriggerable monostable. With the duration being the comparison value.

                  A retriggerable monostable with a period of 20ms will remain triggered as long as the signal is above 50Hz, and will generate pulses when it’s below that. A second retriggerable monostable can “filter” these pulses into a continuous signal.



                  • use a filter slope and a peak detector (just as some cheap FM radios)

                  A filter slope (high-pass or low-pass will do) attenuates different frequencies differently. By detecting the amplitude of the output signal you can compare to a threshold. The higher the filter slope the higher the frequency gain.



                  • use a known pulse size to convert to PWM. (Frequency to voltage conversion).

                  By triggering a known-size pulse with each signal edge (with a monostable or just an edge detector) you convert the signal to PWM whose DC average will be proportional to the frequency. You can then use an analog comparator to detect the transition.



                  Given that you are talking of thousands of signals, any analog solution might be difficult to use reliably with a desired tolerance. Besides, you will need multiple components for each channel; at least 1 IC and multiple passives.



                  If you simply program a 14-pin microcontroller to implement just this function on several channels, you can use 1 IC for 5 channels or so. With much better precision, reliability, and repeatability. Even a 6-pin micro at 1 IC per channel would be smaller and simpler.







                  share|improve this answer












                  share|improve this answer



                  share|improve this answer










                  answered 1 hour ago









                  Edgar BrownEdgar Brown

                  6,4372735




                  6,4372735



























                      draft saved

                      draft discarded
















































                      Thanks for contributing an answer to Electrical Engineering Stack Exchange!


                      • Please be sure to answer the question. Provide details and share your research!

                      But avoid


                      • Asking for help, clarification, or responding to other answers.

                      • Making statements based on opinion; back them up with references or personal experience.

                      Use MathJax to format equations. MathJax reference.


                      To learn more, see our tips on writing great answers.




                      draft saved


                      draft discarded














                      StackExchange.ready(
                      function ()
                      StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2felectronics.stackexchange.com%2fquestions%2f427566%2fconverting-a-variable-frequency-to-ttl-high-and-low-levels-based-on-a-fixed-po%23new-answer', 'question_page');

                      );

                      Post as a guest















                      Required, but never shown





















































                      Required, but never shown














                      Required, but never shown












                      Required, but never shown







                      Required, but never shown

































                      Required, but never shown














                      Required, but never shown












                      Required, but never shown







                      Required, but never shown







                      Popular posts from this blog

                      Are there any AGPL-style licences that require source code modifications to be public? Planned maintenance scheduled April 23, 2019 at 23:30 UTC (7:30pm US/Eastern) Announcing the arrival of Valued Associate #679: Cesar Manara Unicorn Meta Zoo #1: Why another podcast?Force derivative works to be publicAre there any GPL like licenses for Apple App Store?Do you violate the GPL if you provide source code that cannot be compiled?GPL - is it distribution to use libraries in an appliance loaned to customers?Distributing App for free which uses GPL'ed codeModifications of server software under GPL, with web/CLI interfaceDoes using an AGPLv3-licensed library prevent me from dual-licensing my own source code?Can I publish only select code under GPLv3 from a private project?Is there published precedent regarding the scope of covered work that uses AGPL software?If MIT licensed code links to GPL licensed code what should be the license of the resulting binary program?If I use a public API endpoint that has its source code licensed under AGPL in my app, do I need to disclose my source?

                      2013 GY136 Descoberta | Órbita | Referências Menu de navegação«List Of Centaurs and Scattered-Disk Objects»«List of Known Trans-Neptunian Objects»

                      Button changing it's text & action. Good or terrible? The 2019 Stack Overflow Developer Survey Results Are Inchanging text on user mouseoverShould certain functions be “hard to find” for powerusers to discover?Custom liking function - do I need user login?Using different checkbox style for different checkbox behaviorBest Practices: Save and Exit in Software UIInteraction with remote validated formMore efficient UI to progress the user through a complicated process?Designing a popup notice for a gameShould bulk-editing functions be hidden until a table row is selected, or is there a better solution?Is it bad practice to disable (replace) the context menu?